Security Settings

For information on the items ("A", "B", "C", and "No") in the "Import All Function" column, see Import All Function.
Item
Setting Description
DeviceAdmin
NetworkAdmin
Can be set in Remote UI
Import All Function
Name of Item When Exporting with the Remote UI
<Authentication/Password Settings>
<Authentication Function Settings>
<Prohibit Authentication Using Department ID and PIN>
<On>, <Off>
Yes
Yes
Yes
C
Settings/Registration Basic Information
<Lockout Settings>
<Enable Lockout>: <On>, <Off>
No
No
Yes
C
Settings/Registration Basic Information
When <On> is selected:
<Lockout Threshold>: 1 to10 times
<Lockout Period>: 1 to 60 min.
No
No
Yes
C
Settings/Registration Basic Information
<Password Settings>
<Prohibit Caching of Authentication Password>
<On>, <Off>
No
No
Yes
C
Settings/Registration Basic Information
<Display Warning When Default Password Is in Use>
<On>, <Off>
No
No
Yes
C
Settings/Registration Basic Information
<Allow Use of Default Password for Remote Access>
<On>, <Off>
No
No
Yes
C
Settings/Registration Basic Information
<Minimum Length Settings>
<On> (1 to 32 Characters), <Off>
No
No
Yes
C
Settings/Registration Basic Information
<Validity Period Settings>
<On> (1 to 180 days), <Off>
No
No
Yes
C
Settings/Registration Basic Information
<Prohibit Use of 3 or More Identical Consec. Characters>
<On>, <Off>
No
No
Yes
C
Settings/Registration Basic Information
<Use at Least 1 Uppercase Character>
<On>, <Off>
No
No
Yes
C
Settings/Registration Basic Information
<Use at Least 1 Lowercase Character>
<On>, <Off>
No
No
Yes
C
Settings/Registration Basic Information
<Use at Least 1 Digit>
<On>, <Off>
No
No
Yes
C
Settings/Registration Basic Information
<Use at Least 1 Symbol>
<On>, <Off>
No
No
Yes
C
Settings/Registration Basic Information
<Encryption Settings>
<Prohibit Use of Weak Encryption>
<On>, <Off>
<On> is selected:
<Prohibit Use of Key/Certificate with Weak Encryption>: <On>, <Off>
No
No
Yes
C
Settings/Registration Basic Information
<Format Encryption Method to FIPS 140-2>
<On>, <Off>
No
No
Yes
C
Settings/Registration Basic Information
<Verify System at Startup>
<On>, <Off>
No
No
Yes
C
Settings/Registration Basic Information
501S-0Y8