Adjustment for the image position on long sheets cannot be performed using the guide sheet. |
Clean the platen glass and the underside of the feeder before adjustment. Cleaning the Platen Glass/Cleaning the Feeder Use the following conditions to print the guide sheet. Accurate adjustment results may not be obtained if the guide sheet is not printed appropriately. Paper size: A3 or 11" x 17" Finish: Uncoated, 1-Sided Coated, or 2-Sided Coated Type: None (Normal) Basis Weight: Paper that two-sided printing can be performed on and is 80 g/m2 or heavier (paper that is 200 g/m2 or heavier is recommended) If an edge of the test page is cut incorrectly or folded, or the image is not correctly printed on the test page, the message <Correctly place the test page on the platen glass.> may appear during the scanning process. Adjustment may not be performed correctly with some types of paper, such as textured paper with rough surface or colored paper. If adjustment is not performed correctly when <Use Scanner> is selected, select <Do Not Use Scanner> instead. |
The larger the number of output test pages, the more accurate the adjustment is. If specifying multiple output test pages, make sure that all of the test pages are scanned in the order they are output. If the order is changed or the scanning process is not performed successively, the adjustment may not be made correctly. |
Open and close the feeder gently. Make sure that the guide sheet remains aligned when closing the feeder. |
If you need to adjust the image position more precisely after adjusting it using the guide sheet, select <Do Not Use Scanner> and make necessary adjustments for individual adjustment setting items. |