Configuring the Initial Device Settings

This section describes the initial settings specified on the devices managed by this software.
NOTE
The menu positions, screen names, and item names may differ depending on the model of the devices.
1.
Display the network settings screen on the device.
2.
Set the protocol.
Set [TCP/IP Settings] > [Use HTTP] to [On].
When using the Canon protocol, set [Dedicated Port Settings] to [On].
IMPORTANT
Do not set [Dedicated Port Settings] to [Off] for a device while this software is operating. Information will become unable to be retrieved from the device.
3.
Configure the settings for name resolution if the device is set to communicate with only IPv6 addresses.
NOTE
The operation method differs according to the device type.
Configure the DNS settings other than the following according to the operation environment.
imageRUNNER ADVANCE DX/imageRUNNER ADVANCE
Enter the IPv6 address of the DNS server in [TCP/IP Settings] > [DNS Settings] > [DNS Server Address Settings] > [IPv6].
Enter the host name and domain name of the device in [TCP/IP Settings] > [DNS Settings] > [DNS Host/Domain Name Settings] > [IPv6].
Other models
Configure the settings in the Remote UI.
Click [TCP/IP Settings].
Click [Edit] in [IPv6 Settings].
Enter the IPv6 address of the DNS server in [DNS Settings].
Enter the host name and domain name of the device in [Host Name] and [Domain Name].
4.
Set SNMPv1 or SNMPv3.
When using SNMPv1 to communicate with devices
Set [SNMP Settings] > [Use SNMP v. 1] to [On].
Set [MIB Access Permis.] to [Read Only] for the SNMP community name to use for communication with this software.
The setting does not need to be changed if it is already set to [Read/Write].
For devices with a PS print server attached, if it is necessary to set both [Read/Write] and [Read Only], set a name for the [Read/Write] SNMP community name that differs from the [Read Only] SNMP community name.
When using SNMPv3 to communicate with devices
Set [SNMP Settings] > [Use SNMP v. 3] to [On].
Set [MIB Access Permis.] to [Read Only] for the user to use for communication with this software.
The setting does not need to be changed if it is already set to [Read/Write].
Set [Security Settings] to [Authentication On/Encryption On].
IMPORTANT
When setting [Authentication Algorithm] to SHA2, select a hash length other than 224 bit. This software does not support 224 bit hash lengths.
5.
Set [SNMP Settings] > [Reject SNMP Packets While in Sleep Mode] to [Off].
6.