Support for Adjusting the Secondary Transfer Voltage Using the Feeder

You can now adjust the secondary transfer voltage using the feeder in <Paper Type Management Settings>.
This feature can be set when the "Duplex Color Image Reader Unit-P" is attached.

Adjusting the Secondary Transfer Voltage Using the Feeder

1
Press  (Settings/Registration) <Preferences> <Paper Settings><Paper Type Management Settings>.
2
Select the paper to adjust, and press <Details/Edit>.
3
Press <Adj. Secondary Transfer Voltage>  <Change>.
4
Press <Use Scanner>.
5
Press <Chart Print Settings>.
6
Specify the chart settings, and press <Next>.
<Chart Print Type>
To perform fine adjustment, select <For Fine Adjustment>. If major adjustment is required, select <For Coarse Adjustment>.
If <For Fine Adjustment> is selected, charts with adjustment values in increments of ±1 are output.
If <For Coarse Adjustment> is selected, charts with adjustment values in increments corresponding to the status of the machine are output.
<Print Side>
Select a print side to adjust secondary transfer voltage for.
In any of the following cases, select <Front Side Only>.
When <2nd Side of 2-Sided Page> is set to <On> for the custom paper type.
When paper is loaded in the multi-purpose tray and <Paper Type> is set to <2nd Side of 2-Sided Page>.
For information on the paper that can be used for chart when <Both Sides> is selected, see Paper Available for Two-Sided Copying/Two-Sided Printing.
7
Select the paper source with the custom paper type, and press <OK>.
8
Press <Chart Print/Scan>  <Start Printing>
The chart are output.
9
Place the chart.
Place the chart print by following the instruction on the screen.
If a screen appears prompting you to select the thickness of the original, select the thickness of the original you are using. (Appears when <Original Thickness Defaults for Scan from Feeder> is set to <Always Specify>.
10
Press <Start Scanning>.
The chart print is scanned.
If you output the chart print on both sides, place the opposite side of the chart print on the platen glass and press <Start Scanning> again.
If scanning from the feeder, the original does not need to be turned over and placed on its opposite side.
Press <Scan Using Platen Glass> to change to the screen for scanning from the platen glass. However, with the following paper, scanning from the feeder is not possible, and so the screen changes directly to the screen for scanning from the platen glass without <Scan Using Platen Glass> appearing.
Thin 1, Heavy 5-8, 1-Sided Coated, 2-Sided Coated, Matte Coated, Textured 7-8, Tab Paper, Pre-Punched
11
Remove the chart.
12
Press <OK>.
A4EE-00E