Installation Preparations

This section describes the preparations for installing this software.

Checking the Operation Environment of the Computer

Check the system requirements for the computer where this software will be installed.

Confirming the Information Required for Installation

Confirm the following information to set during installation.
IP address or FQDN (fully qualified domain name) of the computer where this software will be installed
Port numbers that can be used by this software
The default values of the port numbers used by this software are indicated below.
Port numbers/protocols used for accessing this software from a Web browser: 443/HTTPS
Port number used for receiving events from devices: 47545
NOTE
The port numbers can be changed. If another application is using these port numbers, decide port numbers for this software to use.

Confirm that the settings on the Remote Monitoring Server are complete

Before installing this software, confirm that the settings on the Remote Monitoring Server are complete.
If devices with the Cloud Connection Agent function are connected to the Remote Monitoring Server via a standalone connection, perform the following operations to connect the devices via this software.
1.
Delete the devices registered to the Remote Monitoring Server via a standalone connection.
2.
Register the RDS version for this software to the Remote Monitoring Server.
3.
Register the devices to the Remote Monitoring Server again as devices monitored by this software.
IMPORTANT
In the following cases, it is necessary to change the RDS version on the Remote Monitoring Server.
When migrating from the RDS Plug-in to this software
When upgrading from an older version of this software