Correcting Copy Images

Before correcting copy images, see "Attention (Correcting Copy Images)."
You do not need to correct (adjust) copy image normally.
Perform this function in case the gradation or density of the output is extremely different from those of the original document.
IMPORTANT
When copy image correction can be performed
The following messages are not appeared in the display.
<End of Cart. Life.>
<Prepare toner cartridge.>
There are no jobs which use the scanner functions and printer functions.
The following paper is loaded in the paper drawer.
- Paper Size: A4 or Letter
- Paper Type: Plain paper or Recycled paper
- Sheets of paper: 1 sheets or more
If you execute copy image adjustment with running out toner
Even you try to perform the adjustment; the image may not be improved.
Change the toner cartridge and redo the adjustment.
1
Press [] (Menu).
2
Select <Adjustment/Maintenance> using [] or [] and press [OK].
3
Select <Copy Image Adjustment> using [] or [] and press [OK].
4
Make sure that paper is loaded, and then press [OK].
Load paper displayed on the screen.
5
Make sure the procedures for the copy image adjustment, and then press [OK].
To perform the auto gradation adjustment, follow the two procedures (print -> scan) displayed on the screen.
A test chart (adj. image 1) is printed.
6
Open the feeder when the screen displayed during the printing disappears.
7
Place the printed paper on the platen glass with the print side face down.
Set the black stripe (A) on the left side.
8
Close the feeder gently.
9
Press [] (Start).
Scanning of the test chart starts.
NOTE
Check the temperature of the installation site
If the room temperature is too low, correction may not be performed properly.
  If <Adjustment failed.> appears
Is the paper loaded correctly?
Load plain paper or recycled paper of A4/Letter size in the paper drawer.
Is the test chart placed on the platen glass correctly?
Place the test chart on the platen glass with the printing side face down and Set the black stripe on the left side.
Has a paper jam occurred?
Remove the jammed paper.
10
When the correction is complete, the screen in Step 3 reappears. Press [] (Menu) to close the menu screen.
11
Remove the test chart (adjusted image 1) placed on the platen glass in Step 7.
024E-0WL