Using the Advanced Mode

Scanning using the advanced mode

1
Display the ScanGear MF.
Start the ScanGear MF using one of the following methods.
Selecting [Display the Scanner Driver] in the MF Toolbox
Starting from an application
2
Click [Advanced Mode].
3
Configure various settings.
4
Click [Preview].
The preview image is displayed.
The document loaded in the feeder cannot be previewed.
5
You can specify the scan area of a document by creating a cropping frame.
6
Click [Scan].

Advanced mode toolbar

To perform all the operations on the toolbar, the preview image is required.
[] (Clear)
Deletes the preview image. The settings for the toolbar and color are reset.
[] (Crop)
Specify the scanning area.
[] (Move)
Moves the enlarged image.
[] (Zoom)
Enlarges or reduces the preview image.
Left-clicking
Enlarges the image.
Right-clicking
Reduces the image.
[] (Left Rotate)
Rotates the image 90 degrees in the left.
[] (Right Rotate)
Rotates the image 90 degrees in the right.
[] (Information)
Displays the information of the scanned image.
[] (Auto Crop)
Selects the cropping area of the image automatically.
[] (Remove Cropping Frame)
Deletes the selected cropping frames.
[Select All Crops]
All the cropping frames reflect the settings made on the [Advanced Mode] tab.
[Zoom]
Rescan the focal cropping area of the preview image at a higher level of magnification.
Once clicked, this button changes to [Undo].

Various settings of the advanced mode

Favorite Settings

You can register the input settings, output settings, image settings, color settings, and detailed settings as a set of favorite settings. The registered favorite settings can be applied to the overall preview image or the scanning area.
IMPORTANT
Items that cannot be registered in favorite settings
Values of width and height in [Input Settings] and [Output Settings]
Activation of the [] (maintaining the proportion of width and height) button in [Input Settings]
Value of [%] (Scale) in [Output Settings]
[User Defined]
Enter and specify each setting value.
[Default]
Resets the current setting to the default value. The preview image is deleted.
[Add/Delete]
Displays the [Add/Delete Favorite Settings] dialog box. You can name and register the current preview image settings. This item is not displayed when there is no preview image.

Input Settings

[Original Input Method]
Selects an input method from the following settings.
[Platen Glass]
[ADF (1-sided)]*
[ADF (2-sided)]*
NOTE
If you change this setting after previewing
The preview image is deleted.
[Input Size]
Select a size of the document to be scanned.
NOTE
If you change this setting after previewing
The preview image is deleted.
If you selected [Platen Glass] or [ADF (1-sided)] from [Original Input Method], you can also enter values to specify the size.
(Width):
Specifies the width of the input size.
(Height):
Specifies the height of the output size.
NOTE
To change the units of measure
Select any of [Pixel], [Inch], and [Millimeter] from the drop-down list on the right.
Image data scanning limitations
The amount of image data that can be scanned depends on the application being used. If the scanning setting value exceeds 21,000 x 30,000 pixels, the image cannot be scanned.
The minimum setting values for images
The minimum setting values are 4 x 4 pixels. (It can be specified when [Output Resolution] is set to 25 dpi.)
To maintain the current width and height proportions of the image
Click [].
[] (Original Orientation)
Shows the direction of scanning paper.
The icon to be displayed varies depending on the settings for [Original Input Method], [Input Size], and [Orientation].
[Orientation]
Click to specify the orientation of the document.
If you selected [ADF (2-sided)] from [Original Input Method], you can also specify [Binding Location].
If you selected [Platen Glass] from [Original Input Method], this setting is unavailable.
[Color Mode]
Selects the type of document and the way in which it is scanned.
[Black and White]
To output documents in monochrome. The image color is divided into white and black at a certain level (threshold), and the image is expressed in 2 colors. See "Color Settings" for the instruction on how to specify a threshold value.
[Grayscale]
Select when scanning black and white photos or monochrome images. The image is expressed in a 0 to 255 scale of black and white.
[Color]
Select when scanning color photos. The image is expressed in 256 levels (8-bit) of R(ed), G(reen), and B(lue).
[Text Enhanced]
Scans text clearly. Select when scanning text using OCR software. The image is expressed in 2 colors of black and white.

Output Settings

[Output Resolution]
Select the scanning resolution from the drop-down list or enter any value between 25 and 9600 dpi to specify the scanning resolution. If you want to use the feeder or the platen glass cover, enter any value between 25 and 600 dpi.
[Output Size]
Select the output size of the scanned image.
If you select [Add/Delete]
The [Add/Delete the Output Size] dialog box will appear, and you can add and delete the custom output size.
If you select [Flexible]
Enter values for width, height, or [%] (Scale). The ratio of width and height is proportionate to the width and height in [Input Settings]. The actual scanning resolution varies depending on a value specified in [%]. You can enter the value for [%] between 25 and 38,400, but the upper limit varies depending on the value of [Output Resolution].
Click [] to change the layout orientation (landscape or portrait). When selecting [Flexible], you cannot use this button.
[Data Size]
Displays the data size of the image scanned using the specified settings.

Image Settings

[Auto Tone]
If [On] is specified, the color tone for the image is adjusted automatically. You can apply this setting when the preview image is displayed.
NOTE
Condition to specify the setting
This setting is available when [Color] or [Grayscale] is selected in [Color Mode].
[Reduce Dust and Scratches]
Reduces dust and scratch marks on photos.
[None]
No reduction of dust and scratch marks will be made.
[Low]
Reduces only small dust and scratch marks.
[Medium]
Normally this setting is recommended.
[High]
Reduces large dust and scratch marks. This may remove delicate parts of the image.
NOTE
Condition to specify the setting
This setting is available when [Color] or [Grayscale] is selected in [Color Mode].
[Fading Correction]
Corrects faded images. Selecting this option enhances the saturation of faded documents, making the image vivid. You can apply this setting when the preview image is displayed.
[None]
No fading correction will be made.
[Low]
Corrects faded images slightly.
[Medium]
Normally this setting is recommended.
[High]
Corrects faded images highly. This may change the tone of the image.
NOTE
Condition to specify the setting
This setting is available when [Color] is selected in [Color Mode] and when [Color Correction] in the [Preferences] dialog box is set to [Recommended].
[Grain Correction]
Smooths out the film grain of the image recorded on fast film. The result is smoother tones and higher overall quality.
[None]
No grain correction will be made.
[Low]
Select this setting when the grain in the picture is not so notable.
[Medium]
This setting is recommended.
[High]
Smoothes out even very notable grain in the picture. This may lower the image sharpness and tonal quality.
NOTE
Condition to specify the setting
This setting is available when [Color] or [Grayscale] is selected in [Color Mode].
Preview display
This setting is not reflected.
[Use Unsharp Mask]
If this option is selected, outline of the image is emphasized, making it sharp. It is effective for scanning photos etc., which have a soft focus.
NOTE
Condition to specify the setting
This setting is available when [Color] or [Grayscale] is selected in [Color Mode].
[Use Descreen]
Select to reduce the distorted pattern (moire) when scanning printed photographs and pictures.
NOTE
Condition to specify the setting
This setting is available when [Color] or [Grayscale] is selected in [Color Mode].
If [Use Unsharp Mask] is selected
Even if [Use Descreen] is selected, some moire effect may remain. In this case, deselect [Use Unsharp Mask].
To apply new setting
Scan the document again.
[Black Text Correction]
If the check box is selected, emphasizes the outline of black text.

Color Settings

Using Color Settings buttons, you can adjust the brightness and contrast of the whole image, specify highlights and shadows, and adjust the contrast and balance in an image.
The color setting buttons to be displayed vary depending on the selected [Color Mode]. When [Text Enhanced] is selected, no Color Settings button is displayed.
When a Color Settings button is clicked, the dialog box appears to specify the corresponding option. Clicking [Reset] resets all the color settings to the default values.
When [Color] or [Grayscale] is selected in [Color Mode]:
When [Black and White] is selected in [Color Mode]:
If you select [Add/Delete] from the drop-down menu, a set of color settings can be registered. For details, see "Tone curve/threshold drop-down list."

Brightness/Contrast

This dialog box enables you to adjust the levels of brightness and contrast of the image.
Click [] to adjust the brightness and contrast diagrammatically.
[Channel]
Select a color to adjust either [Red], [Green], or [Blue], or select [Master] to adjust all three colors together when [Color] is selected in [Color Mode].
When [Grayscale] is selected in [Color Mode], adjust gray color.
[Brightness]
Adjust the brightness by moving [] on the slider or manually entering values from -127 up to 127.
[Contrast]
Adjust the contrast by moving [] on the slider or manually entering values from -127 up to 127.
[Reset]
Resets all the current settings to their default values.

Histogram

You can check how much data clusters at which level of the brightness. You can specify the darkest and brightest levels within an image, cut the levels and expand the middle of the tonal range of the image.
[Channel]
Select a color to adjust either [Red], [Green], or [Blue], or select [Master] to adjust all three colors together when [Color] is selected in [Color Mode].
When [Grayscale] is selected in [Color Mode], adjust gray color.
[] (Black-point eyedropper tool)
Click this button and specify an area which you want to darken the most by clicking in the preview image (or the selected cropping area). You can also manually enter a value from 0 up to 245 or move [] on the slider.
[] (Mid-point eyedropper tool)
Click this button and specify an area where you want to make halftone by clicking in the preview image (or the selected cropping area). You can also manually enter a value from 5 up to 250 or move [] on the slider.
[] (White-point eyedropper tool)
Click this button and specify an area which you want to lighten the most by clicking in the preview image (or the selected cropping area). You can also manually enter a value from 10 up to 255 or move [] on the slider.
[] (Gray Balance eyedropper tool)
To adjust color images, click this button and specify a point at which gray balance is adjusted by clicking in the preview image (or the selected cropping area). The gray color in the scanned image becomes halftone, and other colors are reproduced in their original colors.
[Reset]
Resets all the current settings to their default values.

Tone Curve Settings

This dialog box enables you to adjust the brightness of a specific area of an image by selecting the type of the tone curve.
[Channel]
Select a color to adjust either [Red], [Green], or [Blue], or select [Master] to adjust all three colors together when [Color] is selected in [Color Mode].
When [Grayscale] is selected in [Color Mode], adjust gray color.
[Select Tone Curve]
Select a tone curve type from [No Correction], [Over Exposure], [Under Exposure], [High Contrast], and [Invert the Negative/Positive Image].
[Reset]
Resets all the current settings to their default values.

Final Review

This dialog box enables you to confirm the color settings.

Threshold

You can adjust the threshold setting. By adjusting the threshold, you can sharpen characters in a text document and reduce back-printing such as in newspapers.
NOTE
Threshold
Brightness of color and gray images is expressed by a value between 0 and 255, while brightness of black and white images is expressed by white or black, including colors between black and white. The boundary to divide colors into white and black is called "Threshold."
[Threshold Level]
Adjust the threshold level by moving [] on the slider or manually entering a value from 0 up to 255.
[Reset]
Resets the current setting to the default value.

Tone curve/threshold drop-down list

You can save color settings in a cropping frame. If there are no cropping frames, settings for the whole preview area is saved. You can also read the saved settings to apply them to the selected cropping frame.
[Custom]
You can specify each setting value. The settings can be changed even after applying them.
[Add/Delete]
Opens the [Add/Delete Tone Curve Settings] dialog box ([Add/Delete Threshold Settings] dialog box for when [Black and White] is selected in [Color Mode]). This dialog box enables you to name and register a set of color settings.

Preferences

Clicking [Preferences] in the [Advanced Mode] tab displays the [Preferences] dialog box. You can change the settings for scanning and previewing.

[Preview] tab

[Preview at the Start of ScanGear]
Selects the preview operation when you open the ScanGear MF.
[Automatically Execute Preview]
The preview starts automatically when you open the ScanGear MF.
[Display Saved Preview Image]
Displays the image last previewed.
[None]
The preview image is not displayed.
[Cropping Frame on Previewed Images]
Sets how the cropping frame is displayed when you preview images.
[Execute Auto Cropping on Previewed Images]
The image will be automatically cropped to match the document size.
[Display the Last Frame on Previewed Images]
Displays the last frame.
[None]
No frame is displayed.

[Scan] tab

[Scan without Using ScanGear's Window]
If you are using an application such as OCR software that does not display the ScanGear MF window when scanning, documents are scanned with the application settings. If you want to scan in a specific color mode without using the application settings, specify the setting in this option.
[Text Enhanced]
The document is scanned in a mode equivalent to [Text Enhanced] of [Color Mode], regardless of the application settings.
[Automatically Quit ScanGear after Scanning]
If this item is selected, the [ScanGear MF] dialog box closes automatically after scanning. Depending on the application, the ScanGear MF closes automatically after scanning, regardless of this setting.

[Color Settings] tab

[Color Correction]
Selects the type of color correction.
[Recommended]
Vividly reproduces the tone of a document on the screen.
[Color Matching]
Adjusts color to that of the scanner, monitor, and color printer. If this item is selected, the color setting buttons in the [Advanced Mode] tab are disabled. This setting is available when [Color] is selected in [Color Mode].
[Always Execute the Auto Tone]
Always corrects the image color automatically. This setting is available when [Color] or [Grayscale] is selected in [Color Mode].
[Monitor Gamma]
Adjusts the gamma. You can specify the gamma value (0.10 to 10.00) of the monitor which displays the scanned image. This setting is not reflected in the scanning result when [Black and White] is selected in [Color Mode].
NOTE
When [Color Matching] is selected in [Color Correction]
The value for [Monitor Gamma] is fixed at 1.80.

[Scanner] tab

[Select Folder Where Temporary Files are Saved]
Specifies the folder to save images temporarily. Click [Browse] to specify a folder to save the file.
[Sound Settings]
Sets the scanner to play music during scanning or play a sound when scanning is complete.
[Play Music During Scanning]
Music is played during scanning. Click [Browse] and specify a sound file.
[Play Sound When Scanning is Completed]
Music is played when scanning is completed. Click [Browse] and specify a sound file.
You can specify the following files:
MIDI files (*.mid, *.rmi, *.midi)
Audio files (*.wav, *.aif, *.aiff)
MP3 file (*.mp3)
[Test Scanner]
You can check if the scanner is functioning properly. The [Scanner Diagnostics] dialog box is opened. Click [Start].
0F27-0A6