Automatic Gradation Adjustment

You can recalibrate the machine when you notice irregularities in the colour of the copies or prints, such as when copies turn out to be different from the original in gradation, density, or colour.
This is a precise recalibration that is made to the gradation and density settings of the machine. The procedure involves making test pages and placing them on the platen glass for scanning. Once this is complete, the machine automatically corrects the irregularities.
Automatic gradation adjustment may differ, depending on the optional equipment attached to the machine.
The following two types of gradation adjustments can be made:
Full Adjustment
This is a precise recalibration that is made to the gradation, density, and colour settings of the machine. The procedure involves making test pages and placing them on the platen glass for scanning. Once this is complete, the machine automatically corrects the irregularities.
Quick Adjustment
This is a quick and simple adjustment that is made to the gradation, density, and colour settings of the machine. Recalibrations are made internally without outputting any test pages.
IMPORTANT
The following types of paper can be used with [Auto Adjust Gradation]. Do not use other types of paper.
Type: Thin and Plain
Size: A3, A4, 11" x 17", and LTR
It is recommended that you select [Full Adjust] when performing an automatic gradation adjustment. Select [Quick Adjust] for a quick, but less complete adjustment between regular full adjustment recalibrations.
Make sure that you place the test pages properly. Accurate recalibrations of the gradation and density settings of the machine cannot be made if the test pages are not scanned correctly.
Three test pages are output by the machine during this adjustment. This machine adjusts the toner and print speed according to the paper type. To make effective adjustments, select the correct paper type.
NOTE
Test pages are not counted as part of the copy or print total page counts.

Full Adjustment

1.
Press (Settings/Registration).
2.
Press [Adjustment/Maintenance] → [Adjust Image Quality] → [Auto Adjust Gradation].
3.
Press [Full Adjust].
4.
Select the paper source → press [OK].
5.
Press [Start Printing].
NOTE
If paper appropriate for the test page is not loaded in any paper source, a message asking you to load the appropriate paper appears. Load the appropriate paper in a paper source.
6.
Place the first test page on the platen glass → press [Start Scanning].
* Place the test page face down on the platen glass, with the black bar along the inner edge of the platen glass
7.
Remove the first test page from the platen glass → press [Start Printing].
8.
Place the second test page on the platen glass → press [Start Scanning].
* Place the test page face down on the platen glass, with the black bar along the inner edge of the platen glass
9.
Remove the second test page from the platen glass → press [Start Printing].
10.
Place the third test page on the platen glass → press [Start Scanning].
* Place the test page face down on the platen glass, with the black bar along the inner edge of the platen glass
11.
Remove the third test page from the platen glass.

Quick Adjustment

1.
Press (Settings/Registration).
2.
Press [Adjustment/Maintenance] → [Adjust Image Quality] → [Auto Adjust Gradation].
3.
press [Quick Adjust].
4.
Press [Start].
12HF-07H