<Timer/Energy Settings>

Specify the settings for the time, power consumption, etc.
 
For information on the items ("A", "B", "C", and "No") in the "Import All Function" column, see Import All Function.

<Adjust Time>

 (Settings/Registration)  <Preferences> <Timer/Energy Settings>
You can adjust the time in minutes.
Item
Setting Description
DeviceAdmin
NetworkAdmin
Can be set in Remote UI
Device Information Delivery Available
Import All Function
Name of Item When Exporting with the Remote UI
<Adjust Time>
00:00 to 23:59, in one minute increments
Yes
Yes
No
No
No
-
Even if you change the time from 23:59 to 00:00, the date will not be changed.

Date/Time Settings

 (Settings/Registration)  <Preferences> <Timer/Energy Settings>
Setting the current date and time is very important. For instructions on how to configure the setting, see Setting the Date/Time.
Item
Setting Description
DeviceAdmin
NetworkAdmin
Can be set in Remote UI
Device Information Delivery Available
Import All Function
Name of Item When Exporting with the Remote UI
<Date/Time Settings>
Date and Time Setting (12 digit number)
No
No
Yes
No
No
-
208 V and 120 V machines:
<Time Zone>: UTC-12:00 to UTC-05:00 to UTC+14:00
230 V machine:
<Time Zone>: UTC-12:00 to UTC+09:00*1 to UTC+14:00
No
No
Yes
No
C
Settings/Registration Basic Information
<Daylight Saving Time>: <On>, <Off>
No
No
Yes
No
C
Settings/Registration Basic Information
<Start Date> (<Month>/<Day>/<Time> (0 to 23)),
<End Date> (<Month>/<Day>/<Time> (0 to 23))
No
No
Yes
No
C
Settings/Registration Basic Information
*1: Indicates items with default setting that may differ depending on the region.

<Time Format>

 (Settings/Registration)  <Preferences> <Timer/Energy Settings>
You can set whether to display the time in 24-hour notation or 12-hour notation.
Item
Setting Description
DeviceAdmin
NetworkAdmin
Can be set in Remote UI
Device Information Delivery Available
Import All Function
Name of Item When Exporting with the Remote UI
<Time Format>
208 V and 120 V machines:
<24 Hour>, <12 Hour>
230 V machine:
<24 Hour>, <12 Hour>
No
No
Yes
No
C
Settings/Registration Basic Information
You can also specify to automatically synchronize the date and time with a server on the network using SNTP. Making SNTP Settings

<Quick Startup Settings for Main Power>

 (Settings/Registration)  <Preferences> <Timer/Energy Settings>
If you set this function to <On>, you can reduce the time it takes until you can perform operations on the screen and scan originals after the power is turned ON.
Item
Setting Description
DeviceAdmin
NetworkAdmin
Can be set in Remote UI
Device Information Delivery Available
Import All Function
Name of Item When Exporting with the Remote UI
<Quick Startup Settings for Main Power>
(C7700 Series / C5700 Series Only)
<On>, <Off>
No
No
Yes
Yes
C
Settings/Registration Basic Information
<Quick Startup Settings for Main Power>
(C3700 Series Only)
<On> (<Prioritize Startup Speed>: <On>, <Off>), <Off>
No
No
Yes
Yes
C
Settings/Registration Basic Information
When this function is enabled
Standby power is consumed even when the power is turned OFF.
A tone sounds when the machine is turned ON, or when the machine is turned OFF if you set <Sleep Mode Tone> in <Other Volume Settings> to <On>. (However, the machine may not be able to start up quickly and the tone may not sound, depending on the status of the machine.)
Even if this function is set to 'On', the machine does not startup quickly in the following situations:
When any of the network settings below are set to 'On'
AppleTalk
Wi-Fi
Bluetooth
When turning ON the main power of the machine after turning OFF the main power in any of the conditions below
More than 110 hours have elapsed after quick startup
Operating jobs
Jobs are reserved
Just after using telephone lines
Backing up data
Accessing to the machine via network
After specifying settings which require restarting the machine
Error is occurred
Using the Limited Functions mode
The power cord is disconnected after turning OFF the main power
MEAP applications which do not support quick startup are installed on the machine
When turning ON the main power of the machine in 20 seconds after turning OFF the main power
When turning ON the main power of the machine after eight hours have passed since the machine was turned OFF
When turning ON the main power of the machine after turning OFF the main power from the Remote UI

<Auto Reset Time>

 (Settings/Registration)  <Preferences> <Timer/Energy Settings>
You can specify the time period in which you are logged out and the touch panel display returns to the default setting automatically.
Item
Setting Description
DeviceAdmin
NetworkAdmin
Can be set in Remote UI
Device Information Delivery Available
Import All Function
Name of Item When Exporting with the Remote UI
<Auto Reset Time>
0 min=Off, 10 to 50 seconds in 10 second increments, 1 to 2 to 9 minutes in one minute increments
Yes
Yes
Yes
Yes
C
Settings/Registration Basic Information
If the login service is being used, the machine automatically logs out the user when the Auto Reset Time elapses.
The screen displayed after the Auto Reset initiates differs depending on the following settings.
Setting 1: The settings in [Visual Message Settings] (when [When to Display] is set to [After Logout/Auto Reset])
When Visual Message is not set or after the displayed Visual Message screen is closed, the screen that is specified in Setting 2 is displayed.
Setting 2: The settings in <Function After Auto Reset>
When <Initial Function> is set, the screen specified in <Default Screen after Startup/Restoration> (Setting 3) is displayed.
When <Selected Function> is set, the function before the Auto Reset initiates is displayed. (The specified settings and entered values for each function will be cleared.) However, the <Selected Function> settings may not be correctly reflected, and the screen specified in <Default Screen after Startup/Restoration> may be displayed.
Setting 3: The settings in <Default Screen after Startup/Restoration>

<Restrict Auto Reset Time>

 (Settings/Registration)  <Preferences> <Timer/Energy Settings>
If you set this function to <On>, general users become unable to set <Auto Reset Time> and <Function After Auto Reset>.
Item
Setting Description
DeviceAdmin
NetworkAdmin
Can be set in Remote UI
Device Information Delivery Available
Import All Function
Name of Item When Exporting with the Remote UI
<Restrict Auto Reset Time>
<On>, <Off>
No
No
Yes
Yes
C
Settings/Registration Basic Information

<Function After Auto Reset>

 (Settings/Registration)  <Preferences> <Timer/Energy Settings>
You can set whether the default screen set for <Default Screen after Startup/Restoration> in <Preferences> or the immediately previous screen is displayed at startup after the Auto Reset initiates.
Item
Setting Description
DeviceAdmin
NetworkAdmin
Can be set in Remote UI
Device Information Delivery Available
Import All Function
Name of Item When Exporting with the Remote UI
<Function After Auto Reset>
<Initial Function>, <Selected Function>
Yes
Yes
Yes
Yes
C
Settings/Registration Basic Information
If Visual Message is set to be displayed after the Auto Reset mode initiates, the Visual Message screen is displayed first, regardless of this setting. Configuring the Visual Message Function

<Auto Sleep Time>

 (Settings/Registration)  <Preferences> <Timer/Energy Settings>
You can set the time until the machine automatically enters the Sleep mode if no operations are performed.
Item
Setting Description
DeviceAdmin
NetworkAdmin
Can be set in Remote UI
Device Information Delivery Available
Import All Function
Name of Item When Exporting with the Remote UI
<Auto Sleep Time>
10 secs, 1 min, 2 mins, 10 mins, 15 mins, 20 mins, 30 mins, 40 mins, 50 mins, 1 hr, 90 mins*1, 2 hrs*1
Yes
Yes
Yes
Yes
C
Settings/Registration Basic Information
*1 May not appear on some models.
It is recommended that the default value is used for this setting.

<Sleep Mode Energy Use>

 (Settings/Registration)  <Preferences> <Timer/Energy Settings>
You can set the amount of energy that the machine consumes when it is in the Sleep mode.
Item
Setting Description
DeviceAdmin
NetworkAdmin
Can be set in Remote UI
Device Information Delivery Available
Import All Function
Name of Item When Exporting with the Remote UI
<Sleep Mode Energy Use>
<Low>, <High>
Yes
Yes
Yes
Yes
C
Settings/Registration Basic Information
<Compensate for Network Comm.>: <On>, <Off>
If the machine is connected to a computer using a USB cable, depending on the timing for entering the sleep mode, the machine may be unable to receive data correctly. Reactivate the machine from the sleep mode, then execute the job again.
The energy consumption level may be the same as when <High> is set even when <Low> is set, depending on the status of the machine.
When performing wireless communication while <Sleep Mode Energy Use> is set to <Low>, and <Wireless LAN Settings> or <Use Bluetooth> is enabled, <Compensate for Network Comm.> changes to <On>.
If the energy consumption level is set to <Low>, communication failure may occur, depending on the network utility software you are using. To avoid this, press the Energy Saver key to cancel the Sleep mode before using the machine.

<Auto Sleep Weekly Timer>

 (Settings/Registration)  <Preferences> <Timer/Energy Settings>
You can set the time that the machine automatically enters the Sleep mode each day of the week.
Item
Setting Description
DeviceAdmin
NetworkAdmin
Can be set in Remote UI
Device Information Delivery Available
Import All Function
Name of Item When Exporting with the Remote UI
<Auto Sleep Weekly Timer>
<Sunday> to <Saturday>, 00:00 to 23:59, in one minute increments
Yes
Yes
Yes
Yes
C
Settings/Registration Basic Information
If you set both the <Auto Sleep Time> and <Auto Sleep Weekly Timer>, the <Auto Sleep Time> setting is given priority.

<Time Settings for Auto Adjust Gradation>

 (Settings/Registration)  <Preferences> <Timer/Energy Settings>
You can automatically perform the automatic gradation adjustment at a set time every day.
Item
Setting Description
DeviceAdmin
NetworkAdmin
Can be set in Remote UI
Device Information Delivery Available
Import All Function
Name of Item When Exporting with the Remote UI
<Time Settings for Auto Adjust Gradation>
<Sunday> to <Saturday>, 00:00 to 23:59, in one minute increments
Yes
Yes
Yes
Yes
C
Settings/Registration Basic Information

<Sleep Mode Exit Time Settings>

 (Settings/Registration)  <Preferences> <Timer/Energy Settings>
You can set the time at which the machine recovers from the Sleep mode.
Item
Setting Description
DeviceAdmin
NetworkAdmin
Can be set in Remote UI
Device Information Delivery Available
Import All Function
Name of Item When Exporting with the Remote UI
<Sleep Mode Exit Time Settings>
00:00 to 23:59, in one minute increments
Yes
Yes
Yes
Yes
C
Settings/Registration Basic Information

<Sleep Mode Eco Exit>

 (Settings/Registration)  <Preferences> <Timer/Energy Settings>
When you cancel sleep mode and start the operation, you can activate necessary functions sequentially. The control panel is activated first, followed by other functions activated in response to the user's operations. You can save energy and lower noise by not activating unnecessary functions.
Item
Setting Description
DeviceAdmin
NetworkAdmin
Can be set in Remote UI
Device Information Delivery Available
Import All Function
Name of Item When Exporting with the Remote UI
<Sleep Mode Eco Exit>
<On>, <Off>
Yes
Yes
Yes
No
C
Settings/Registration Basic Information

<Use Motion Sensor>

 (Settings/Registration)  <Preferences> <Timer/Energy Settings>
When the motion sensor detects a person near the machine, the machine exits the Sleep mode automatically. You can adjust the accuracy for detecting people by changing the sensor sensitivity.
 Sensor Sensitivity
The following four sensitivity settings are available for <Sensor Sensitivity>. When a user stays in the detection area longer than a certain period of time, the machine exits the Sleep mode.
 
Sensitivity Setting
Sensitivity Level
Low
With this sensitivity level, the machine does not recover even if someone passes by slowly.
Standard
With this sensitivity level, the machine does not recover even if someone passes by at a regular speed.
Slightly High
With this sensitivity level, the recovery speed is prioritized more than the "Standard" level.
High
With this sensitivity level, the recovery speed is given top priority.
 
 
Item
Setting Description
DeviceAdmin
NetworkAdmin
Can be set in Remote UI
Device Information Delivery Available
Import All Function
Name of Item When Exporting with the Remote UI
<Use Motion Sensor>
<On>, <Off>
Yes
Yes
Yes
No
C
Settings/Registration Basic Information
<Sensor Sensitivity>: <Lower>, <Higher> (4 levels)
Yes
Yes
Yes
No
A
Settings/Registration Basic Information
Depending on the sensitivity setting, the machine may recover from the Sleep mode even when not in use. If you are disturbed by the operation sounds made when this happens, you can reduce the noise level by setting <Sleep Mode Eco Exit> to <On>.
If you feel that something is wrong with the motion sensor, change the sensitivity setting in <Sensor Sensitivity> or turn the motion sensor <Off>.
79JC-0KR