<TCP/IP Settings>

Specify the settings that enable the machine to be used on a TCP/IP network.
 
For information on the items ("A", "B", "C", and "No") in the "Import All Function" column, see Import All Function.

<SMB Client Settings>

 (Settings/Registration) <Preferences> <Network> <TCP/IP Settings>
Specify the settings to use when the machine connects to a network as an SMB client. Setting the SMB Client
Item
Setting Description
DeviceAdmin
NetworkAdmin
Can be set in Remote UI
Device Information Delivery Available
Import All Function
Name of Item When Exporting with the Remote UI
<SMB Client Settings>
<Authentication Type>: <NTLMv1>, <NTLMv2>
No
Yes
Yes
No
C
Settings/Registration Basic Information
<Require SMB Signature for Connection>: <On>, <Off>
No
Yes
Yes
No
C
Settings/Registration Basic Information
<Require Encryption for Connection>: <On>, <Off>
No
Yes
Yes
No
C
Settings/Registration Basic Information
<Timeout>: 3 to 30 to 300 sec.
No
Yes
Yes
No
C
Settings/Registration Basic Information

<Specify SMB Client Version>

 (Settings/Registration) <Preferences> <Network> <TCP/IP Settings>
Specify the version of SMB to use with the SMB client. Setting the SMB Client
Item
Setting Description
DeviceAdmin
NetworkAdmin
Can be set in Remote UI
Device Information Delivery Available
Import All Function
Name of Item When Exporting with the Remote UI
<Specify SMB Client Version>
<1.0>: <On>, <Off>
No
Yes
Yes
No
C
Settings/Registration Basic Information
<2.0>: <On>, <Off>
No
Yes
Yes
No
C
Settings/Registration Basic Information
<3.0>: <On>, <Off>
No
Yes
Yes
No
C
Settings/Registration Basic Information
<3.1>: <On>, <Off>
No
Yes
Yes
No
C
Settings/Registration Basic Information
Use the same version of SMB with the SMB server and SMB client. SMB cannot be used if the versions differ.

<Use HTTP>

 (Settings/Registration) <Preferences> <Network> <TCP/IP Settings>
Enable or disable HTTP setting.
Item
Setting Description
DeviceAdmin
NetworkAdmin
Can be set in Remote UI
Device Information Delivery Available
Import All Function
Name of Item When Exporting with the Remote UI
<Use HTTP>
<On>, <Off>
No
Yes
Yes
Yes
C
Settings/Registration Basic Information
By specifying this setting as <On>, you can open a necessary port. However, it is recommended that you specify it as <Off>, if a port is not used. If you leave the port open, an unauthorized user may access the machine.
If you set this to <Off>, the following settings are also set to <Off>.
<Remote UI>

<TLS Settings>

 (Settings/Registration) <Preferences> <Network> <TCP/IP Settings>
You can set a key pair, TLS version, and encryption algorithm to use after confirming that a machine uses TLS encrypted communication. Configuring the Key and Certificate for TLS
Item
Setting Description
DeviceAdmin
NetworkAdmin
Can be set in Remote UI
Device Information Delivery Available
Import All Function
Name of Item When Exporting with the Remote UI
<Key and Certificate>
<Set as Default Key>: <Yes>, <No>
No
Yes
Yes
No
No
-
<Certificate Details> (<Version>, <Serial Number>, <Signature Algorithm>, <Issued To>, <Validity Start Date>, <Validity End Date>, <Issuer>, <Public Key>, <Certificate Thumbprint>, <Issued To (Altn. Name)>, <Verify Certificate>)
No
Yes
Yes
No
No
-
<Display Use Location> (Displays what the key pair is being used for)
No
Yes
Yes
No
No
-
<Specify Allowed Versions>
<Maximum Version>: <TLS 1.0>, <TLS 1.1>, <TLS 1.2>, <TLS 1.3>
No
Yes
Yes
No
C
Settings/Registration Basic Information
<Minimum Version>: <TLS 1.0>, <TLS 1.1>, <TLS 1.2>, <TLS 1.3>
No
Yes
Yes
No
C
Settings/Registration Basic Information
<Encryption Algorithm Settings>
<AES-CBC (256-bit)>: <On>, <Off>
No
Yes
Yes
No
C
Settings/Registration Basic Information
<AES-GCM (256-bit)>: <On>, <Off>
No
Yes
Yes
No
C
Settings/Registration Basic Information
<3DES-CBC>: <On>, <Off>
No
Yes
Yes
No
C
Settings/Registration Basic Information
<AES-CBC (128-bit)>: <On>, <Off>
No
Yes
Yes
No
C
Settings/Registration Basic Information
<AES-GCM (128-bit)>: <On>, <Off>
No
Yes
Yes
No
C
Settings/Registration Basic Information
<CHACHA20- POLY1305>: <On>, <Off>
No
Yes
Yes
No
C
Settings/Registration Basic Information
<Key Exchange Algorithm Settings>
<RSA>: <On>, <Off>
No
Yes
Yes
No
C
Settings/Registration Basic Information
<ECDHE>: <On>, <Off>
No
Yes
Yes
No
C
Settings/Registration Basic Information
<X25519>: <On>, <Off>
No
Yes
Yes
No
C
Settings/Registration Basic Information
<Signature Algorithm Settings>
<RSA>: <On>, <Off>
No
Yes
Yes
No
C
Settings/Registration Basic Information
<ECDSA>: <On>, <Off>
No
Yes
Yes
No
C
Settings/Registration Basic Information
<HMAC Algorithm Settings>
<SHA1>: <On>, <Off>
No
Yes
Yes
No
C
Settings/Registration Basic Information
<SHA256>: <On>, <Off>
No
Yes
Yes
No
C
Settings/Registration Basic Information
<SHA384>: <On>, <Off>
No
Yes
Yes
No
C
Settings/Registration Basic Information

<Proxy Settings>

 (Settings/Registration) <Preferences> <Network> <TCP/IP Settings>
Specify settings for the proxy. Setting a Proxy
Item
Setting Description
DeviceAdmin
NetworkAdmin
Can be set in Remote UI
Device Information Delivery Available
Import All Function
Name of Item When Exporting with the Remote UI
<Proxy Settings>
<Use Proxy>: <On>, <Off>
No
Yes
Yes
No
C
Settings/Registration Basic Information
<Server Address> (IP Address or FQDN)
No
Yes
Yes
No
C
Settings/Registration Basic Information
<Port Number>: 1 to 80 to 65535
No
Yes
Yes
No
C
Settings/Registration Basic Information
<Use Proxy within Same Domain>: <On>, <Off>
No
Yes
Yes
No
C
Settings/Registration Basic Information
<Set Authentication>
<Use Proxy Authentication>: <On>, <Off>
No
Yes
Yes
No
C
Settings/Registration Basic Information
<User Name> (24 characters maximum)
No
Yes
Yes
No
C
Settings/Registration Basic Information
<Password> (24 characters maximum)
No
Yes
Yes
No
C
Settings/Registration Basic Information

[TCP/IP Option Settings]

Start the Remote UI [Settings/Registration]  [Network Settings]
Specify the TCP option window scale and MTU size.
Item
Setting Description
DeviceAdmin
NetworkAdmin
Can be set in Remote UI
Device Information Delivery Available
Import All Function
Name of Item When Exporting with the Remote UI
[TCP/IP Option Settings]
[Use Window Scale Option]: [On], [Off]
No
Yes
Yes
No
C
Settings/Registration Basic Information
[MTU Size]: 600 to 1500 bytes (600-1500)
No
Yes
Yes
No
C
Settings/Registration Basic Information
This setting can only be specified from the Remote UI.
A097-0AU