Adjusting the Image Position Using the Guide Sheet (When Using the Platen Glass)

If you want to adjust the alignment of the images printed both on the front and back side of the paper quickly,you can make an adjustment by scanning the test pages with the use of the guide sheet. This adjustment can be performed when the Duplex Color Image Reader Unit-P is attached.
Guide Sheet
   
   
 
  
Test page (2-Sided): Standard size
 
Test page (2-Sided): Long sheet
  
(Front Side)(Back Side)
 
(Front Side)(Back Side)
  
 
  
Before making adjustments, clean the platen glass. Cleaning the Platen Glass
Use the following conditions to print the guide sheet. Accurate adjustment results may not be obtained if the guide sheet is not printed appropriately.
Paper size: A3 or 11" x 17"
Finish: Uncoated, 1-Sided Coated, or 2-Sided Coated
Type: Normal
Basis Weight: Paper that two-sided printing can be performed on and is 80 g/m2 or heavier (paper that is 200 g/m2 or heavier is recommended)
If an edge of the test page is cut incorrectly or folded, or the image is not correctly printed on the test page, the message <Correctly place the test page on the platen glass.> may appear during the scanning process.
Adjustment may not be performed correctly with some types of paper, such as textured paper with rough surface or colored paper. If adjustment is not performed correctly when <Use Scanner> is selected, select <Do Not Use Scanner> instead.

1
Press <Change> for <Adjust Image Position>.
2
Press <Use Scanner>.
3
Select <Platen Glass> in <Location for Scanning Test Page>, and press <Print> in <Output Guide Sheet>.
4
Select the paper source that contains the paper to use, and press <Start Printing>.
The guide sheet is printed.
5
Enter the number of test page to make, and press <Next>.
The larger the number of output test pages, the more accurate the adjustment is.
If specifying multiple output test pages, make sure that all of the test pages are scanned in the order they are output.
6
Select the paper source that contains the paper type to adjust, and press <Start Printing>.
The test page is printed.
7
Place the guide sheet on the platen glass, and align the arrow of the sheet with the arrow on the platen glass.
8
Align the mark  (blue) on the test page for the first scan operation with the mark on the guide sheet.
9
Close the feeder, and press <Start Scanning>.
Open and close the feeder gently. Make sure that the guide sheet remains aligned when closing the feeder.
10
Turn the test page upside down, and align the mark  (yellow) on the test page for the second scan operation with the mark on the guide sheet press <Start Scanning>.
11
Turn the test page over, and align the mark  (green) on the test page for the third scan operation with the mark on the guide sheet  press <Start Scanning>.
12
Turn the test page upside down, and align the mark  (red) on the test page for the fourth scan operation with the mark on the guide sheet  press <Start Scanning>.
13
Adjustment is complete.
If you have specified multiple output test pages, repeat steps 6 to 10 for all of the output test pages. In this case, adjustment is complete when all of the test pages have been scanned.
Make sure that the test pages are scanned in the order they are output.
If you need to adjust the image position more precisely after adjusting it using the guide sheet, select <Do Not Use Scanner> and make necessary adjustments for individual adjustment setting items.
A717-083