Inspecting the Breaker

This machine has a breaker that detects excess current or leakage current.
Before testing the breaker, turn Off the power of the machine and check that the subsequent shutdown process is completed. Be sure to test the breaker about once a month.
1
Turn OFF the power and remove the power cord from the outlet. Turning OFF the Machine
Check the operation status of the machine before turning it OFF. Turning OFF the machine during an operation may cancel the operation or result in data corruption or damage.
Wait at least three seconds after the Main Power indicator on the control panel turns off before unplugging the power cord.
2
Push the test button on the back of the machine with the tip of a ball-point pen or a similar object.
Briefly push the test button.
Do not use the test button to turn the power ON and OFF.
3
Confirm that the breaker lever is switched to the OFF position.
If the breaker lever is not switched to the OFF position, repeat step 2. If the breaker lever is not switched to the OFF position, despite carrying out the above procedure two or three times, contact your dealer or service representative.
4
Switch the breaker lever to ON.
5
Plug the power cord into the outlet, and turn ON the machine. Turning ON the Machine
AXE3-10E