[Sub Line Settings]

Configure the sub line settings when a setting other than [Off] is selected for [Sub Line] in [Select Interface].
* Values in red text indicate the default setting for each item.
[ Settings/Registration] [Preferences] [Network] [Sub Line Settings]
Automatically or manually set the IPv4 address to use for the sub line. Setting the IPv4 Address of the Sub Line
[DHCP]
On, Off
[IP Address]: 0.0.0.0
[Subnet Mask]: 0.0.0.0
[Gateway Address]: 0.0.0.0
[ Settings/Registration] [Preferences] [Network] [Sub Line Settings]
Select whether to connect mobile devices to the main line or sub line when the machine communicates with mobile devices.
[Main Line], [Sub Line]
[ Settings/Registration] [Preferences] [Network] [Sub Line Settings]
Configure whether to enhance security for [Scan and Store] or [Access Stored Files].
When the machine is connected to two separate networks with the setting set to [On], you can restrict sending, receiving, and viewing files via the network.
[On], [Off]
[ Settings/Registration] [Preferences] [Network] [Sub Line Settings]
Configure the sub line of Ethernet communication mode and specify whether to enable the EEE function. Manually Configuring the Ethernet Settings
You can also check the current transmission speed and the MAC address of the wired LAN. Checking the MAC Address of the Wired LAN
* When you set [Ethernet Type] to [1000BASE-T], [Communication Mode] is set to [Full Duplex].
* Depending on the network environment, the connection between the machine and the network may become unstable. In that case, setting [Use EEE] to [Off] may improve the situation.
For C7100 Series and C5100 Series
[Auto Detect]
[On], [Off]
[Communication Mode]
[Half Duplex], [Full Duplex]
[Ethernet Type]
[10BASE-T], [100BASE-TX], [1000BASE-T]
[Current Transmission Speed]
[MAC Address]
[Use EEE]
[On], [Off]
For C3100 Series
[Auto Detect]
[On], [Off]
[Communication Mode]
[Half Duplex], [Full Duplex]
[Ethernet Type]
[10BASE-T], [100BASE-TX], [1000BASE-T]
[Current Transmission Speed]
[MAC Address]
[Use EEE]*1
[On], [Off]
*1The default setting varies depending on the model.
[ Settings/Registration] [Preferences] [Network]  [Sub Line Settings]
Configure the IEEE 802.1X settings to be used for the sub line. Using IEEE 802.1X
[Use IEEE 802.1X]
[On], [Off]
[Login Name]
[Verify Authentication Server Certificate]
[On], [Off]
[Verify Authentication Server Name]
[On], [Off]
[Authentication Server Name]
[Use TLS]
[On], [Off]
[Key and Certificate]
[Set as Default Key]
[Certificate Details]
[Version]
[Serial Number]
[Signature Algorithm]
[Issued To]
[Validity Start Date]
[Validity End Date]
[Issuer]
[Public Key]
[Certificate Thumbprint]
[Issued To (Altn. Name)]
[Verify Certificate]
[Display Use Location]
[Use TTLS]
[On], [Off]
[<TTLS Settings (TTLS Protocol)>]
[MSCHAPv2], [PAP]
[Use PEAP]
[On], [Off]
[User Name]
[Password]
[Same User Name as Login Name]
[On], [Off]
[ Settings/Registration] [Preferences] [Network] [Sub Line Settings]
Configure the IP address filter and MAC address filter settings for the sub line.
[ Settings/Registration] [Preferences] [Network] [Sub Line Settings]
Configure the DNS and proxy settings to use when performing specific system data communication over the sub line.