Calibrating the Gradation

Gradation is the gradual changing of the color depth and brightness. If the gradation is not reproduced correctly and the printed data greatly differs from the source data or original, calibrate the gradation (calibration).
You cannot perform calibration while printing or scanning or when there is insufficient toner.
Gradation can be calibrated in two ways: Quick Adjust or Full Adjust.
First, try Quick Adjust for simple calibration. If you do not see an improvement, perform Full Adjust to calibrate more accurately.
IMPORTANT
Toner is used during calibration.
Performing frequent calibration may affect the lifetime of the toner.
If the symptoms do not improve even after performing calibration, the remaining amount of toner may be low. It is recommended to check the remaining amount of toner, and replace any toner containers, as needed.

Simple Calibration (Quick Adjust)

This section describes how to perform calibration (Quick Adjust) using the control panel.
You can also use Remote UI from a computer to perform calibration (Quick Adjust). Managing the Machine from a Computer (Remote UI)
1
On the control panel, press [ Settings/Registration] in the [Home] screen or other screen. [Home] Screen
The [Settings/Registration] screen is displayed.
2
Press [Adjustment/Maintenance]  [Adjust Image Quality]  [Auto Adjust Gradation].
The [Auto Adjust Gradation] screen is displayed.
3
Select the paper type to calibrate.
You can skip this step if the prompt to select the paper type is not displayed. Proceed to Step 4. Calibration will be applied to all paper types.
4
Press [Quick Adjust].
The [Quick Adjust] screen is displayed.
5
Press [Start].
Calibration is performed.
When calibration is complete, [Adjustment is complete.] is displayed.
If the result after performing Quick Adjust is not satisfactory, perform Full Adjust. Calibrating More Accurately (Full Adjust)
NOTE
You can configure the settings to perform Quick Adjust automatically at regular periods. [Time Settings for Auto Adjust Gradation]

Calibrating More Accurately (Full Adjust)

Scan the test page printed with the machine on the feeder or platen glass to calibrate the gradation more accurately.
The result calibrated here is used until Full Adjust is performed next time.
Paper Sizes and Types Usable for Calibration
Size: A3, A4, 11" x 17", LTR, 8K
Type: Plain 1 to Plain 3, Heavy 1 to Heavy 7
 
Use the control panel to perform calibration (Full Adjust). You cannot perform calibration (Full Adjust) using Remote UI from a computer.
1
On the control panel, press [ Settings/Registration] in the [Home] screen or other screen. [Home] Screen
The [Settings/Registration] screen is displayed.
2
Press [Adjustment/Maintenance]  [Adjust Image Quality]  [Auto Adjust Gradation].
The [Auto Adjust Gradation] screen is displayed.
3
Configure the calibration settings.
If you do not select [Use Feeder When Performing Full Adjust], scan the printed test page using the platen glass.
If you select [On] for [Initialize When Using Full Adjust], the previous Full Adjust data is initialized and calibrated.
4
Select the paper type to calibrate.
You can skip this step if the prompt to select the paper type is not displayed. Proceed to Step 5. Calibration will be applied to all paper types.
5
Press [Full Adjust].
The [Select Paper] screen is displayed. You can check the usable paper sizes and currently selected paper type.
6
Select the paper source with the loaded usable paper, and press [OK].
7
Press [Start Printing].
A test page is printed.
8
Scan the test page to perform calibration.
If the test page was printed on Heavy 6 or Heavy 7, use the platen glass to scan.
Using the Feeder to Scan
1
Follow the instructions on the screen to load the test page in the feeder.
2
Press [Start Scanning].
The test page is scanned, and calibration is performed.
When calibration is complete, [Adjustment is complete.] is displayed.
Using the Platen Glass to Scan
1
Open the feeder.
2
Follow the instructions on the screen to place the test page on the platen glass.
3
Gently close the feeder.
4
Press [Start Scanning].
The test page is scanned, and calibration is performed.
When calibration is complete, [Adjustment is complete.] is displayed.
5
Remove the test page from the platen glass.
NOTE
When Changing the Calibration Level
You can use [Adjustment Level] on the screen in Step 2 to set the range to apply Quick Adjust. By default, [By Paper Type Group] is set, and you can make more accurate calibrations for each paper type selected in Step 4. When you select [Simple], calibration accuracy decreases, but the time it takes for calibration becomes shorter. Administrator privileges are required to configure the setting.